REFCO

Gobi II Universal Condensate Pump 3004045

(No reviews yet) Write a Review
SKU:
44854
UPC:
7640154084735
MPN:
3004045
Condition:
New
Package Weight:
2.30 LBS
$172.13

Out of stock

Description

Gobi II Universal Condensate Pump 3004045

Universal Application - 6,000 Btu/H up to 120,000 Btu/H (100-240 VAC)

Integrated replaceable 10 A fuse

Unique digital water level sensor

Diagnostic LED - Ensures correct initial installation and assists in dianostics

USB connection

Quiet mode, configure pump performance to AC unit capacity


The all new Gobi II condensate pump has been completely redesigned retaining all the good features you like and upgrading everything else. The Gobi II has a massive flow range allowing its use from 6,000 Btu/H (1.75kW) up to 120,000 Btu/H (35 kW). Its digital water sensor, Universal voltage and user configurable flow ensure it is the strongest, quietest under A/C mounted condensate pump on the market today.


Details:

  • Gobi-II Condensate Pump
  • Type Universal Voltage
  • Discharge Size 1/4 Inch Outer Diameter
  • Overall Dimensions 9.84 Inch x 11.81 Inch x 2.1 Inch
  • Flow Rate 11 GPH
  • Discharge Head 65.6 Foot
  • Power Rating 12 Watt
  • Input Supply Rating 100 to 240 Volt AC 50 to 60 Hertz
  • Temperature Rating 41 to 104 Deg F
  • Inclusions/Features Power Cable, Alarm Cable, Screw, Star Tube and Stop Siphon Device, Factory Installed Fuse, Red Screw Anchors, Cable Ties
  • Application HVAC/R
  • Applicable Standard UL778, CSA C22.2 #68, CE, ETL (Canada and US), DIN EN ISO 3741
  • RoHS Compliant
  • Enclosure Type IP-44
  • Maximum Suction 10 Foot
  • Maximum Horizontal Run 300 Foot at 0 Head
  • Sound Rating 20 dBA at 1 Meter (Running)
  • Discharge Star Tube Size 1/4 Inch Outer Diameter x 3.3 Foot Length
  • Alarm Relay 10 Amp NO/NC Contact
  • Quiet mode Installer configurable pump performance using dip-switches to optimize each individual installation for the best performance and sound parameters
  • Diagnostic LED Patented two color long-life LED to ensure correct initial installation and to assist in diagnostics on future service calls
  • USB connection Patented access for wholesalers or installing contractors to review pump history
  • Digital sensor Unique digital water level sensor with no moving parts to get stuck or clogged
  • Universal application: Widest application range for exposed mount pumps in the market from 6000 Btu/H to 120000 Btu/H (1.75 kW to 35 kW)
  • RoHS Compliant

Safety Information


California Proposition 65 Warning SymbolWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
This product and other products on our site may contain a chemical known to the state of California to cause cancer or birth defects or other reproductive harm. Visit the state of California's website to learn more about Proposition 65.

Many of our items should be installed by a trained HVAC technician. With purchase of this item, you are agreeing to follow any and all safety guidelines provided by the manufacturer and to have the item installed by a trained HVAC technician as necessary. Your professional installer assumes all responsibility for injury or property damage that may result.

View AllClose

Warranty & Returns

The items we offer on our website are professional grade products that are designed and built to be installed by licensed, professional tradesmen. Because of the professional install these products carry a longer warranty, different than found in similar products offered by big box stores for do it yourselfers. We encourage you to be a licensed HVAC contractor or to hire a Licensed HVAC contractor to be sure you can truly get the manufacturer's warranty. Many manufacturers will request a copy of the contractor license or a bill of install to start the warranty procedure. HVAC Wholesale Direct is a distributor and is not responsible for labor claims, supplies or refrigerant cost recovery or rejected manufacturer's warranty due to misapplication or for operating outside the terms of a manufacturer's warranty.

box graphic

30-Day Hassle-Free Return Policy
After 30 days, we will still accept returns but with a 15% Restocking Fee for up to 90 Days

Return terms and conditions: Item(s) must be new and unused in the original packaging with all original documentation included.

Upon receipt of the returned item(s) an inspection will be performed to ensure the above terms and conditions have been met.
If they have, we will issue a refund back to the original method of payment used at time of sale, less our original cost of shipping. If the terms and conditions have not been met, we will contact you to arrange for the items to be returned to you at your expense.

You are responsible for return shipping costs.
We recommend you insure the shipment against loss or damage. Any return shipping damage claims will be your responsibility.


Return Instructions - Non Damage Items

You must ...

  • Request a return via our Contact Us link
  • Include your order / invoice number
  • Provide a reason for your return request
  • State if you want a replacement or a refund

Once we receive your request, we will respond with either an authorization to return, or deny the request with an explanation. If the request is authorized, we will also provide instructions on how and where to return the purchase. Upon receipt of the item(s) back, an inspection will be performed to determine if the item(s) can be returned to the shelf or not. If they can, we will comply with your request for a replacement item(s) or a refund. Refunds will always be issued back to the method of payment used for the original purchase. If the item(s) can not be returned to the shelf for resale, they will be returned to you at your expense.

Items Damaged During Shipment

Occasionally, items are damaged in shipment. It is the buyer's responsibility to inspect for damage upon receipt from the shipping / delivery company. It's best to refuse the delivery and notate the damage on the driver's bill. It's always best to take a picture and let us know, so we can make arrangements to get you a replacement as quickly as possible. Once you accept the shipment, any damage claims at that time are between the delivery company and the buyer. We inspect every item / shipment for damage prior to tendering the items to the delivery company.

Defective Items

If your reason for returning the item in the instructions above is due to a manufacturer defect, you must state that in your return request, as it will affect the instructions for returning the item. Many manufacturers have specific procedures that must be followed in order to process these claims. A detailed description of the defect must be provided. You may be asked to provide additional information such as, a service ticket showing the diagnosis from a licensed HVAC professional, pictures of the defect, etc. These additional pieces of information will help to expedite the process in many cases. Some manufacturers will not proceed without that additional information.

HVAC Wholesale Direct vendor network is made up of some of the finest manufactures of HVAC products. We will be here to assist you. We however, do not have any control over the manufacturers and their warranty practices and make no claim on honoring warranty on behalf of any manufacturer. HVAC Wholesale Direct is not responsible for shipping or freight charges for any warranty claims made that we are helping to facilitate. We issue credit after we receive credit from the manufacturer.

Electrical Parts

Electrical parts, such as capacitors, contactors, transformers, and thermostats are NON-ReturnABLE. HVAC Wholesale Direct is not liable for improper selection and/or installation of electrical parts and controls.

At the end of the day we are people doing business with people in a modern environment. We want you to be happy with your experience with our company. We promise to work with all of our customers, within good reason, to resolve any conflicts, whether defective or mis-ordered to your satisfaction.

View AllClose

Specifications

Type:
Universal Voltage
Discharge Size:
1/4 Inch Outer Diameter
Overall Dimensions:
9.84 Inch x 11.81 Inch x 2.1 Inch
Flow Rate:
11 GPH
Discharge Head:
65.6 Foot
Power Rating:
12 Watt
Input Supply Rating:
100 to 240 Volt AC 50 to 60 Hertz
Temperature Rating:
41 to 104 Deg F
Inclusions/Features:
Power Cable, Alarm Cable, Screw, Star Tube and Stop Siphon Device, Factory Installed Fuse, Red Screw Anchors, Cable Ties
Application:
HVAC/R
Applicable Standard:
UL778, CSA C22.2 #68, CE, ETL (Canada and US), DIN EN ISO 3741
UOM:
ea
View AllClose

0 Reviews

View AllClose